How to Install the Remodel Kit

Remodel Housing

Learn how to easily install your remodel housing.

Classic Module + Classic Trim

Learn how to easily install your classic module and classic trim.

Classic Adjustable Module
+ Classic Trim

Learn how to easily install your classic adjustable module and classic trim.

How to Install LUSA Remodel Recessed Lights in an Existing Ceiling (DIY Guide)

How to Install LUSA Remodel Recessed Lights in an Existing Ceiling (DIY Guide)

Key takeaway

Remodel recessed lights install from below without opening the ceiling: cut a hole, wire the housing, push it up, lock the spring clips, then plug in the light. The LUSA Lighting Remodel Kit fits drywall ceilings 5/8 to 1 1/4 inches thick and takes Round, Square, Surface or Sloped Ceiling trims.

  • Time per fixture: 15 to 30 minutes for a DIYer, plus any time to run new wire.
  • Tools: drill, hole saw, stud finder, voltage tester, wire strippers and wire nuts.
  • Call an electrician: for no power at the ceiling, a new circuit or switch, or aluminum or knob-and-tube wiring.

LUSA Lighting provides installation videos and instructions for every Remodel Kit.

What tools do you need to install remodel or canless recessed lights?

Both LUSA kits install from below a finished drywall ceiling with a drill, the matching hole saw, a stud finder, a voltage tester and wire strippers. The Remodel Kit adds a housing and more trim styles, and fits thicker ceilings, while the Canless Kit needs the least space above the ceiling. An existing 6-inch can calls for the 6" to 4" Conversion Kit instead.

Option Best for Time per fixture Tools Cons
LUSA Remodel Kit Existing ceilings 5/8 to 1.25 inches thick, or where Surface or Sloped Ceiling trims are wanted 15 to 30 min (DIY) Drill, 3 5/8" or 4 1/2" hole saw, stud finder, voltage tester, wire strippers, wire nuts Needs just over 4 inches above a 5/8 inch ceiling for the 4-inch housing (4.69 inch housing height)
LUSA Canless Kit Shallow ceilings, tight joist bays and the simplest DIY install 15 to 30 min (DIY) Drill, 4 1/8" or 3 5/8" hole saw, stud finder, voltage tester, wire strippers, wire nuts Round or Square trims only; drywall up to 5/8"
LUSA 6" to 4" Conversion Kit Replacing an existing 6-inch can without cutting new holes Two sessions (joint compound and paint must dry) Screwdriver or drill, drywall tape, joint compound, taping knife, sanding sponge, paint Needs a 6-inch can at least 3 inches deep; drywall finishing

Prefer to watch first? The LUSA Remodel Kit install video shows each step below.

Step 1: Plan the layout and the power source

Mark each light's center, then use a stud finder to keep every mark clear of joists. Confirm the ceiling is drywall 5/8 to 1 1/4 inches thick with enough open space above it for the housing: just over 4 inches for a 4-inch Remodel Kit or 3 7/8 inches for a 3-inch kit in a 5/8 inch ceiling. Then pick the power source and plan the cable path.

  • Clearance: Space needed above the ceiling is the housing height minus the ceiling thickness. The 4-inch housing is 4.69 inches tall and the 3-inch housing is 4.41 inches tall. These measurements are for installation with Romex (NM cable); conduit needs additional depth but is uncommon in homes.
  • Spacing: For general lighting, space LUSA lights 5 to 7 feet apart.
  • Power source: The simplest source is an existing ceiling light box controlled by a wall switch. If there is no switched power in the ceiling, see the electrician section below.
  • Cable path: Plan the run from the source to the first light, then light to light. Runs that follow the joists are the easiest to fish; crossing joists usually means attic access or drilling.

Step 2: Turn off the power and cut the holes

Turn off the circuit at the breaker and confirm it is dead with a voltage tester at the power source. Cut each opening with a hole saw: 3 5/8 inches for the 3-inch housing or 4 1/2 inches for the 4-inch housing. Clean debris from the edges so the housing lip can sit flat.

  • Safety: Wear safety glasses and keep the drill square to the ceiling so the hole stays round.
  • Insulation: The Remodel Housing is IC rated and ASTM E283 Air Tight, so it can sit in contact with attic insulation.

Step 3: Run power cable to each light

With the power still off, run NM cable with ground from the power source to the first light's hole, then from each light to the next. Fish the cable through the joist bays between holes and leave about 12 inches hanging from every opening. When you finish, each hole has its cables ready to connect.

  • At the source: Remove the old fixture and connect the new cable to the wires that fed it: black to the switched hot, white to neutral and ground to ground. The box must stay accessible, so close it with a blank cover plate.
  • Cable size: Match the existing circuit: 14-gauge cable on a 15-amp circuit, 12-gauge on a 20-amp circuit. The Remodel Housing is approved for #12 AWG wire.
  • Light to light: Every light except the last gets two cables: one coming in and one going out to the next light. The last light gets one.
  • Code: Follow local code and the NEC for how cable is routed, secured and protected.

Step 4: Mount the Remodel Housing and splice the hardwire adapter

Remove the hardwire adapter from the housing and set it aside. Route the cables into the housing through the Romex knockouts, push the housing up until its plastic lip is flush with the ceiling, then push each spring clip outward until it clicks. Splice the supply wires to the hardwire adapter inside the housing with wire nuts, leaving the ground wire available in the housing for Step 5.

  • Housing as junction box: The Remodel Housing is the junction box, so all splices are made inside it. The hardwire adapter gives the module an easy plug-in IDEAL connection in Step 5.
  • Spring clips: Keep holding the housing flush while you engage the first clip, then repeat for the second.
  • Next light: Include the outgoing cable to the next light in the same splices, black with black and white with white. Splice the incoming and outgoing ground wires together, leaving a ground lead free for the module.
  • Capacity: The 4-inch housing has four Romex knockouts and two 1/2 inch knockouts, the 3-inch has two of each, and both are approved for eight #12 AWG conductors (four in, four out).

Step 5: Install the light module and trim

Set the module's Brightness Switch and snap the trim onto the module until the tension clips click. Attach the module's green ground wire to the ground wire from the supply cable in the housing first, then plug the module into the hardwire adapter's IDEAL connector. Push the module into the housing, press the trim to the ceiling and rotate it up to a quarter turn to lock it flush.

  • Brightness Switch: Downlight: 350 lm (5W) for soft light, 750 lm (9W) for 7 to 9 ft ceilings, 950 lm (12W) for 9 to 12 ft ceilings. Adjustable: 500 lm (6W), 750 lm (8.5W) or 900 lm (10W).
  • Trim options: Downlight: Round, Square, Surface or Sloped Ceiling, in White or Black. Adjustable: Round or Square in White. Both in 4-inch or 3-inch sizes.
  • Adjustable module: Tilt the light source up to 35 degrees (press where the arrow shows) and face it toward the target before pushing it in. It rotates 360 degrees.
  • Fit check: If a gap remains, press the trim firmly against the ceiling and rotate again, staying within a quarter turn. Note the pivot direction of the Sloped Ceiling trim and position it accordingly.

Step 6: Restore power and test

Turn the breaker back on and test the lights at the switch. On a compatible dimmer, the LUSA Remodel Kit dims to 5% and warms from 3000K to 2200K with Natural Warm Dim. If one light or the rest of the chain stays off, turn the power off again and recheck the connections, starting at the last light that works.

  • Dimmers: Use a TRIAC or ELV dimmer rated for LED loads.
  • Wet areas: The Classic Downlight module with standard trims is UL listed for wet locations. The Classic Adjustable and the Sloped Ceiling trim are rated for damp locations.

When should you call an electrician to install remodel recessed lights?

Installing LUSA Remodel Kits is a DIY job when power is already in the ceiling, such as an existing light on a working switch, and you can reach the joist bays to route cable, e.g. simple runs or attic access. Call a licensed electrician when the job needs a new circuit or switch, when the wiring is old or damaged, or when cable cannot be routed without opening the ceiling.

Situation DIY or electrician
Adding lights fed from an existing ceiling light box on a working circuit DIY
No power or switch at the new location, or a new circuit is needed Electrician
Aluminum or knob-and-tube wiring Electrician
Brittle, cracked or damaged cable insulation Electrician
Circuit already loaded close to its limit with other fixtures or outlets Electrician
No attic access or open joist bay to route cable Electrician

Many cities require an electrical permit for new circuits or new wiring, and some require one for any added fixture. Check with the local building department before starting. A licensed electrician usually pulls the permit and schedules the inspection.

Watch the LUSA Remodel Housing install video to see the wiring steps before deciding.

LUSA canless recessed lighting installation FAQ

How long does it take to install one remodel recessed light?

15 to 30 minutes for a DIYer, covering the hole cut, wiring the housing, clipping it into the ceiling and installing the LUSA Classic module and trim. A licensed electrician is usually faster. Running new cable to each light is the variable: it depends on joist direction, attic access and distance from the power source, so plan extra time for any light that needs a new cable run.

What size hole do I cut for a LUSA Remodel Housing?

Cut a 3 5/8 inch hole for the 3-inch LUSA Remodel Housing and a 4 1/2 inch hole for the 4-inch housing, using a hole saw on a drill. Clean debris from the edge so the housing's plastic lip sits flush. The housing fits drywall ceilings from 5/8 to 1 1/4 inches thick and locks in place with two pre-installed spring clips.

How much space do remodel recessed lights need above the ceiling?

Subtract the ceiling thickness from the housing height. For installations with Romex, the 4-inch LUSA Remodel Housing is 4.69 inches tall, so a 5/8 inch ceiling needs just over 4 inches of open space above it. The 3-inch housing is 4.41 inches tall and needs 3 7/8 inches. If the space is tighter, the LUSA Canless Kit needs only about 2.5 inches above a ceiling up to 5/8 inch thick.

Should I choose remodel or canless recessed lights?

Choose the LUSA Canless Kit for the simplest install and shallow spaces in ceilings up to 5/8 inch thick. Choose the LUSA Remodel Kit for thicker ceilings up to 1 1/4 inches, for Surface or Sloped Ceiling trims, or for 20-amp circuits, since the housing is approved for #12 AWG wire. Both are IC rated and Air Tight, and both dim to 5% with Natural Warm Dim.

Can remodel recessed lights touch insulation?

Yes. The LUSA Remodel Housing is IC rated (Insulation Contact) and ASTM E283 certified Air Tight, so insulation can rest against it and conditioned air does not leak into the attic through the fixture. That makes it a good fit for top-floor ceilings below an insulated attic. The Classic module and trim are also Energy Star, Title 24 JA8 and Declare listed.

Ready to start? Shop the LUSA Remodel Kit in 3-inch or 4-inch sizes, or watch every LUSA installation video before you pick up the drill.